Line Reactor, Fault Current 22000 Amps, Continuous current 3000 Amps, P/N 5758CLR

Product Overview

The details of the line reactor part number 5758CLR is shown below. The line reactor consists of three inductors. Each inductor is housed inside a separate enclosure  Three inductor are required for one line reactor application.






Three inductors are required to build one line reactor application. 
Only one inductor is shown above.



Specifications:


  • Line Reactor, P/N 5758CLR
  • Rating: 480 VAC, 3000 Amps continuous
  • Fault Current or CLR current: 22,000 Amps
  • Inductance: 33.3 uH ± 25% per short circuit study
  • Copper bus bar: 4″ x 15″ x 1/2″ with 20 holes
  • Epoxy coating on winding
  • Calculated coil resistance R DC = 0.000044 Ω
  • Calculated temperature rise: 48°C
  • Winding to enclosure, 3000 VAC Hipot
  • Enclosure for each inductor: 50″ H x 36″ x 36″



The customer application is shown below:




The photo of a similar enclosure is shown below. Three inductor are housed inside three separate enclosures. 




The voltage drop across the current limiting inductor at different current levels is shown in Table A:




Related Links:






All our line reactors are custom built to order. Let us know the continuous current and fault limiting current to design a 
line reactor which is suitable for your application. To discuss your specific application, please call us toll free at (800) 595-7096, or send us an email at info@lcmagnetics.com.




September 11, 2013

42 Amps / 30.94 mH Current Limiting Reactor, P/N 6278CLR, Fault Current: 1200 Amps, High Voltage Application inside an oil filled enclosure

Product Overview

Current Limiting Reactors are used for line reactors, inrush current limiting, and surge current limiter applications. Current Limiting Reactors (CLR) develops a higher voltage drop across the CLRs when the current through the CLRs increases. Current limit reactors are gapped inductor intended to reduce the short circuit currents passing through the circuit breaker in the power system.

The photo of the inrush current limiter inside an oil filled enclosure, part number 6278CLR is shown below:





Medium Voltage CLR, Oil filled enclosure for P/N 6278CLR

Specifications:

  • Current-Limiting Reactor, Oil filled, 42 Amps continuous, 60 Hz, P/N 6278CLR 
  • Rating: 14000 VAC, 1 PH, 60 Hz, 42 amps continuous 
  • Inductance: 30.94 mH ± 25%
  • Fault current: 1200 Amps
  • 490 VAC drop is estimated across the CLR at 42 amps continuous current. 
  • When 42 amps increase momentarily to a catastrophic fault condition to 1200 A, CLR develops 14000 VAC across it. Eventually, the circuit breaker will trip and inhibit the fault condition. 
  • Core is gapped. Without gap, core will saturate at 490 VAC voltage drop. With gap, the core will saturate at voltages higher than 490 VAC. 
  • Oil filled enclosure: 6 feet H x 8 feet W x 5 feet D

    The customer application of the Oil Filled CLR is shown below. The three fault limiting reactors are connected with the circuit breaker for power source protection.


    The voltage drop across the fault current limiter at different current levels is shown in Table A:

    Table A




    L/C Magnetics is a Current Limiting Reactor manufacturer . To discuss your specific application, please call us toll free at (800) 595-7096, or send us an email at info@lcmagnetics.com.

    September 9, 2013

    400 Amps / 66 uH Current Limiting Reactor, P/N 6265CLR, Fault Current: 21000 Amps, inside an indoor enclosure

    Product Overview

    Current Limiting Reactors are used for line reactors, inrush current limiting, and surge current limiter applications. Current Limiting Reactors (CLR) develops a higher voltage drop across the CLRs when the current through the CLRs increases. Current limit reactors are gapped inductors intended to reduce the short circuit currents passing through the circuit breaker in the power system.

    The photo of an open core and coil dry type inrush current limiter, part number 6265L is shown below. Three gapped inductors, P/N 6265L are required for one CLR application.



    Fault Current Limiter, L (1, 2) = 66 uH +/- 25%, 400 Amps, P/N 6265L

    Specifications:

    • Current-Limiting Reactor, Dry type, P/N 6265CLR
    • Inductance: 66 µH ± 15%, 400 amps continuous 
    • 10 VAC drop is estimated across the CLR at 400 amps continuous current. 
    • Fault current: 21000 Amps 
    • Copper bus bar: 2” x 1/4” with one hole 
    • Temperature rise: 23°C 
    • Three inductors will be housed inside an indoor enclosure, 25”H x 36”W x 26”D 
    • Three each of P/N 6265L are required for one system. 
    • P/N 6265CLR is one enclosure with three P/N 6265L
    • Estimated weight: 750 lbs

    Three 66 uH, 400 Amps fault limiting reactors will be housed inside an indoor enclosure as shown below:
     

    Three P/N 6265L inside one enclosure (P/N 6265CLR)

    The voltage drop across the current limiting inductor at different current level is shown in the table A below:

    Table A


    L/C Magnetics is a Current Limiting Reactor manufacturer. To discuss your specific application, please call us toll free at (800) 595-7096, or send us an email at info@lcmagnetics.com.

    August 12, 2013

    4000 Amps / 18.57 uH Current Limiting Reactor, P/N 19016CLR, Fault Current: 75000 Amps with indoor enclosure

    Product Overview

    Current Limiting Reactors are used for line reactors, inrush current limiting, and surge current limiter applications. Current Limiting Reactors (CLR) develops a higher voltage drop across the CLRs when the current through the CLRs increases. Current limit reactors are gapped inductors intended to reduce the short circuit currents passing through the circuit breaker in the power system.

    The photo of the open core and coil dry type inrush current limiter, P/N 19016L is shown below. Three are required for one CLR application.



    Fault Current Limiter, L (1, 2) = 18.57 uH +/- 15%, 4000 Amps, P/N 19016L

    Specifications:

    • Current-Limiting Reactor, dry type, 4000 Amps continuous, 60 Hz, P/N 19016CLR 
    • Three single phase gapped inductors are required in one indoor enclosure.
    • Rating: 480 VAC, 1 PH, 60 Hz, 4000 amps continuous
    • Inductance: 18.57 uH ± 15% (per short circuit study performed by the customer)
    • 28 VAC drop is estimated across the inductor at 4000 amps continuous current. 
    • Total temperature rise: 43°C
    • Copper temperature rise: 23.5°C
    • Core temperature rise: 23.8°C
    • Copper bus bar: 4” x 3/4” with ten holes
    • NEMA 1 enclosure, 50”H x 65”W x 36”D. 
    • Fault current: 75,000 Amps
    • P/N 19016CLR consists of three inductors, P/N 19016L inside a NEMA 1 enclosure, 50”H x 65”W x 36”D 
    • Estimated weight: 3000 lbs approximately

    The three fault limiting reactors P/N 19016L are installed on a platform assembly as shown below. The complete assembly will be housed inside an indoor enclosure, 50"H x 65" x 36"D.


    Three P/N 19016L on a platform assembly

    The customer application is shown below:






    The voltage drops across the current limiting inductor at different current levels are shown in Table A below:

    Table A




    The platform assembly is housed inside the enclosure, 50"H x 65"W x 36"D. The photo of the enclosure is shown below. The 3000 lbs unit can be moved with a pallet jack



    P/N 19016CLR can be moved with a pallet jack or a fork lift


    L/C Magnetics is a Current Limiting Reactor manufacturer. To discuss your specific application, please call us toll free at (800) 595-7096, or send us an email at info@lcmagnetics.com.

    April 1, 2013

    480 Amps / 37 uH Current Limiting Reactor, P/N 18885CLR, Fault Current: 20000 Amps, inside an indoor enclosure

    Product Overview

    Current Limiting Reactors are used for line reactors, inrush current limiting, and surge current limiter applications. Current Limiting Reactors (CLR) develops a higher voltage drop across the CLRs when the current through the CLRs increases. Current limit reactors are gapped inductor intended to reduce the short circuit currents passing through the circuit breaker in the power system.

    An example of a 480 Amps CLR, part number 18885CLR is shown below. Three fault limiting reactors are installed in one indoor enclosure.



    P/N 18885CLR

    Specifications:

    • Current-Limiting Reactor, dry type, 480 Amps, 3 PH, 60 Hz, P/N 18885CLR 
    • Fault current: 20000 Amps 
    • Inductance: 37 uH ± 25% 
    • Three single phase gapped inductors are used for a three phase application. 
    • Enclosure dimensions: 24” H x 20” W x 9” D approximately 
    • Four louvers are installed on the enclosure for free airflow 
    • 6.7 VAC drop is estimated across the CLR at 480 amps continuous current. 
    • When 480 amps increase momentarily to a catastrophic fault condition to 20000 A, CLR develops 277 VAC across it. Eventually, the circuit breaker will trip and inhibit the fault condition. 
    • Copper bus bar: 2” x 1/4” thick with one hole 
    • Core is gapped. Without gap, core will saturate at 6.7 VAC voltage drop. With gap, the core will saturate at voltages higher than 6.7 VAC. 
    • It is recommended that the unit should be placed in a horizontal position as the three single phase inductors inside the enclosure are heavy.

    Three single phase gapped inductors are used for a three phase application. The photo and schematic of a inrush current limiter are shown below.



    Fault Current Limiter, L (1, 2) = 37 uH +/- 25%, 400 Amps

    The customer application for the custom Current Limiting Reactor is shown below. The three gapped inductors are connected with the circuit breaker for power source protection.


    The voltage drop across the current limiting inductor at different current level is shown in the Table A below:


    Table A




    L/C Magnetics is a manufacturer of Custom Current Limiting Reactors. To discuss your specific application, please call us toll free at (800) 595-7096, or send us an email at info@lcmagnetics.com.